Carrier fj4d product data - Product Data A11263 Representative drawing only. Some product models may vary. The 59SC6A Multipoise Comfort™ Condensing Gas Furnace features year-round electrical efficiency when paired with a compatible condensing unit. Energy efficiency is at the heart of this furnace with up to 96.5% AFUE, gas efficiency and the electrically-efficient

 
Product Data. FX4D Comfort Series Fan Coil Sizes 019 thru 061 AIR HANDLER TECHNOLOGY AT ITS FINEST. Comfort eries Fan Coil izes 019 thru 061 Product Data AIR HANDLER TECHNOLOGY AT IT FINET The fan coils combine the proven technology of Carrier fan coil units with Puron, the environmentally sound refrigerant. More information. Coryxkenshin age

The Un-carrier turns the tables when it comes to 5G coverage, though, leading the pack with over 41% of the country covered by its 5G data network. You can find even more details on each network's data coverages—and who has the best coverage in your area—at our coverage comparison guide . There is no data available for this product. FCU COMFORT PURON 5.0T 208/230-1. Replacement for. fb4cnP042L00 - Fan Coil, 3.5T Base Multi-Poise All Aluminum; FX4DNF043000 - FCU 15S COMFORT PURON 3.5T W/ ECM MOTOR; FX4DNF043T00 - FCU 15S COMFORT PURON 3.5T TIN PLATEDOverview. Having an evaporator coil properly matched to your outdoor unit is critical to getting the most out of your air conditioner or heat pump. Carrier ® evaporator coils are designed and manufactured for durability and appropriate system fit to assure you consistent performance year after year. California residents please see Proposition 65.In today’s fast-paced world, staying connected is essential for both personal and professional purposes. Whether you’re a digital nomad, a small business owner, or simply someone w...1,800 to 15,000 Cfm. Carrier's AERO 39L series air handlers are compact and fully assembled. They combine versatility with economical, dependable performance for heating, cooling, ventilation, and VAV (variable air volume) applications. Galvanized steel panels ensure structural integrity under all operating conditions.Carrier FJ4 is a fan coil unit designed for flexible installation in various orientations, including upflow, downflow, and horizontal. It's compatible with R-410A refrigerant air … There is no data available for this product. FCU COMFORT PURON 5.0T 208/230-1. 5: Carrier FJ4 Base Series Fan Coil, Sizes 18 to 60 Product Data (FJ4D-01PD.pdf) 6: Carrier FJ4D Base Series Fan Coil Price Page (FJ4D-C-01PP.pdf) 8: FB4, FE4, FF1E, FFM, FG4, FH4, FJ4, FT4, FV4, FX4, FZ4, PF4, FMA, F54, FY5Residential Fan Coil Units Service and Maintenance Instructions (SM-FANCOIL-09.pdf) 10: FJ4 Fan Coil Units …GH5S: Product Data Manufacturer reserves the right to change, at any time, specifications and designs without notice and without obligations. 3 Vapor Line Sizing and Cooling Capacity Loss Acceptable vapor line diameters provide adequate oil return to the compressor while avoiding excessive capacity loss. The suction line diametersPage 38 SELECTION PROCEDURE (WITH 50TCQA07 EXAMPLE) (Selection software by Carrier saves time by performing many of the steps below.) Determine cooling and heating loads. The required heating capacity is 45,000 Btuh. There- fore, 20,700 Btuh (45,000 – 24,300) additional elec- Given: tric heat is required.Discover the pros and cons of Heil and Carrier air conditioners to help you make an informed decision. Learn which one is the best fit for you. Expert Advice On Improving Your Home...Carrier FJ4 is a fan coil unit designed for flexible installation in various orientations, including upflow, downflow, and horizontal. It's compatible with R-410A refrigerant air … FJ4: Product Data Manufacturer reserves the right to change, at any time, specifications and designs without notice and without obligations. 13. PERFORMANCE DATA (cont.) * Use copper wire only. Use 75_C only in this application. When using non-metallic (NM) sheathed cable, wire size required should be based on that of 60_C conductors, instead ... Product Line: Comfort™ Sx.e Vendor: Carrier (20080) Tonnage: 2 The Comfort ™ FJ4 fan coil utilizes a high-efficiency, multi-speed blower motor to provide comfort options. Paired correctly with an outdoor air conditioner or heat pump, it can aid efficiency to help you save on your heating and cooling energy bills. ...EASY TO INSTALL AND SERVICE. A- -coil design for maximum surface area. A13303. FMU4X & FMU4Z -- Uncased Horizontal Fan Coil (FMU4Z model shown) Multiple electrical, refrigerant lineset and drain line entry for application flexibility. Primary and secondary drain connections exit from the back or side of the cabinet.25SCA5: Product Data Manufacturer reserves the right to change, at any time, specifications and designs without notice and without obligations. 3 Vapor Line Sizing and Cooling Capacity Loss Acceptable vapor line diameters provide adequate oil return to the compressor while avoiding excessive capacity loss. The suction line diametersThis tough Comfort series model is designed to withstand the rigors of your environment and is backed by one of the best seacoast warranties you'll find for a heat pump. This very affordable Comfort series model offers efficiency high enough to be ENERGY STAR ® qualified on select sizes. Like all Comfort series heat pumps our coastal model is ...The unit is shipped with a Puron refrigerant TXV (sizes 18–60). STANDARD FEATURES. Multi-tap ECM (electronic commutating motor) motors – all sizes. Integrated motor controls, with 90-sec off TDR function, have replaced integrated circuit board. Five available speed tags to meet a wide range of applications.Carrier West Training – HVAC TrainingNeed a data entry company in Mumbai? Read reviews & compare projects by leading data entry services. Find a company today! Development Most Popular Emerging Tech Development Langua... System Description. Outdoor−mounted, air−cooled, split−system air conditioner unit suitable for ground or rooftop installation. Unit consists of a hermetic compressor, an air−cooled coil, propeller−type condenser fan, and a control box. Unit will discharge supply air upward as shown on contract drawings. 5: Carrier FJ4 Base Series Fan Coil, Sizes 18 to 60 Product Data (FJ4D-01PD.pdf) 6: Carrier FJ4D Base Series Fan Coil Price Page (FJ4D-C-01PP.pdf) 8: FB4, FE4, FF1E, FFM, FG4, FH4, FJ4, FT4, FV4, FX4, FZ4, PF4, FMA, F54, FY5Residential Fan Coil Units Service and Maintenance Instructions (SM-FANCOIL-09.pdf) 10: FJ4 Fan Coil Units Sizes 018 to ...Discover the pros and cons of Heil and Carrier air conditioners to help you make an informed decision. Learn which one is the best fit for you. Expert Advice On Improving Your Home...Overview. Performance series heat pumps offer that perfect balance between budget limits you may have today and your desire for long-term energy savings. The 25SPA5 boasts cooling efficiencies of up to 15.2 SEER2. And, like other Carrier heat pumps, it's designed to be Hybrid Heat® system compatible to help you save on heating costs in winter too.Clorox bleach is one of the most popular and widely used cleaning products on the market. It is a powerful disinfectant and stain remover, but it also carries certain risks. Clorox... AIR HANDLER TECHNOLOGY AT ITS FINEST. The FJ4 fan coil has the proven technology of Carrier fan coil units with Puron® refrigerant as well as vertical and horizontal applications. The design features contoured condensate pans with rugged drain connections, ensuring that little water is left in the unit at the end of the cooling duty cycle. As an Energy Starr Partner, Carrier Corporation has determined that this product meets the Energy Starr guidelines for energy efficiency. Refer to the combination ratings in the Product Data for system combinations that meet Energy Starr guidelines. NOTE: Ratings contained in this document are subject to change at any time.38MURA: Product Data Manufacturer reserves the right to change, at any time, specif ications and designs without notice and without obligations. 2 MODEL NUMBER NOMENCLATURE A220411 A220412 NOMINAL CAPACITY 18 - 1.5 Tons 24 - 2 Tons 30 - 2.5 Tons 36 - 3 Tons 48 - 4 Tons 60 - 5 Tons A - REGULAR HEAT B - HIGH HEAT M M …System Description. Outdoor−mounted, air−cooled, split−system air conditioner unit suitable for ground or rooftop installation. Unit consists of a hermetic compressor, an air−cooled coil, propeller−type condenser fan, and a control box. Unit will discharge supply air upward as shown on contract drawings.The Un-carrier turns the tables when it comes to 5G coverage, though, leading the pack with over 41% of the country covered by its 5G data network. You can find even more details on each network's data coverages—and who has the best coverage in your area—at our coverage comparison guide .This product has been designed and manufactured to meet Energy Star®criteria for energy efficiency when matched with appropriate coil components. However, proper refrigerant charge and proper air flow are critical to achieve rated capacity and efficiency. Installation of this product should follow all manufacturing refrigerantProduct Data This unit has been designed utilizing Carrier’s Puron refrigerant. The environmentally sound refrigerant allows you to make a responsible decision in the protection of the earth’s ozone layer. NOTE: Ratings contained in this document are subject to change at any time. Always refer to the AHRI directory (www.ahridirectory.org) forEfficiency. 14.3 - 15.2 SEER2 / 11.0 - 12.5 EER2 / 7.5 - 8.1 HSPF2 (depending on unit size and indoor combination installed) Microtube technology refrigeration system. Indoor air quality accessories available. Sound. Sound levels as low as 69 dBA with accessory sound blanket. Comfort. System supports programmable or standard thermostat controls.F = Fan Coil / Product J =Type / Tier 4 = Puron® / Refrigerant Type D = Major Series N = 208/230V, 1 ph, 60 Hz / Electrical ... Coil circuiting has also been updated to make the most of all Carrier heat pumps and air conditioners. Units come with solid state fan controls, 1-inch (25mm) thick insulation with R-value of 4.2, multi-speed motors ...AIR HANDLER TECHNOLOGY AT ITS FINEST. The FJ4 fan coil has the proven technology of Carrier fan coil units with Puron® refrigerant as well as vertical and horizontal applications. The design features contoured condensate pans with rugged drain connections, ensuring that little water is left in the unit at the end of the cooling duty cycle.5: Carrier FJ4 Base Series Fan Coil, Sizes 18 to 60 Product Data (FJ4D-01PD.pdf) 6: Carrier FJ4D Base Series Fan Coil Price Page (FJ4D-C-01PP.pdf) 8: FB4, FE4, FF1E, FFM, FG4, FH4, FJ4, FT4, FV4, FX4, FZ4, PF4, FMA, F54, FY5Residential Fan Coil Units Service and Maintenance Instructions (SM-FANCOIL-09.pdf) 10: FJ4 Fan Coil Units …Overview. The Comfort ™ FX4D fan coil utilizes a high-efficiency, multi-speed blower motor to provide comfort options. Paired correctly with an outdoor air conditioner or heat pump, …The single point wiring kit acts as a jumper between L1 and L3 lugs, and between the L2 and L4 lugs. This allows the installer to run two heavy-gauge, high-voltage wires into the fan coil rather than 4 light-gauge, high-voltage wires. SUGGESTED USE: Fan coils with 15- and 20-kW fused heaters only. Filter Kit (12 pack) The kit consists of 12 fan ...GH5S: Product Data Manufacturer reserves the right to change, at any time, specifications and designs without notice and without obligations. 3 Vapor Line Sizing and Cooling Capacity Loss Acceptable vapor line diameters provide adequate oil return to the compressor while avoiding excessive capacity loss. The suction line diametersFan Coils /. FCU COMFORT PURON 4.0T 208/230-1. Need help with your order? We have the depth of experience and inventoried stock plus technical support to handle your job from the smallest to the largest! 781-322-8800.In this digital age, smartphones have become an essential part of our lives. Whether it’s for communication, productivity, or entertainment, we rely on our phones and the apps inst...Carrier fan coils. It comes in a pre-painted galvanized steel casing with 1-in. insulation and has a 3-speed motor in the full range of sizes 018 through 070. All units are equipped with an AccuRater® metering device and are also shipped with a cleanable, permanent framed filter. The FC4C is a deluxe design fan coil incorporating all the featuresLEGACYt LINE FAN COIL. SIZES 019 THRU 061. Product Data. The FX4D fan coils combine the proven technology of Bryant fan. coil units with Puron®, the environmentally sound refrigerant. These fan coils are loaded with popular features. Factory- -installed, refrigerant- -specific thermostatic expansion valves (TXV) are.Show all. View and Download Carrier FX4D product data online. Comfort FX4D Series Fan Coil Sizes 019 thru 061. FX4D fan pdf manual download. Also for: Fx4d series, Comfort fx4dnf019, Comfort fx4dnf025, Comfort fx4dnf031, Comfort fx4dnf037, Comfort fx4dnf043, Comfort fx4dnf049, Comfort fx4dnf061.This Comfort system offers that perfect balance between budget limits you may have today and your desire for long-term energy savings. It wraps together the summer comfort of an air conditioner with winter warmth from a gas furnace with a durable stainless steel heat exchanger. It also comes with a louvered hail guard for enhanced coil protection.In today’s fast-paced digital world, businesses rely heavily on accurate and efficient data entry for their day-to-day operations. However, many business owners underestimate the i...New direct drive - EcoBlue™ Technology indoor fan system uses Vane Axial fan design & electronically commutated motor. Single-stage cooling capacity 04-06 models, two-stage on 07-30 models. SEERs up to 14.0, IEER of 15.0. Gas efficiencies up to 82%. Cooling operating range up to 115 °F (46°C) and down to 40°F (4°C) using winter start kit.10-year parts limited warranty upon timely registration. 1. FV4C. Performance series fan coil with a variable-speed fan for premium energy savings capabilities and comfort features. 1. The Comfort multi speed fan coil (FX4D) offers efficiency support for outdoor units, with your budget and home comfort in mind.10-year parts limited warranty upon timely registration. 1. Compatible with Infinity system outdoor units and includes a variable-speed fan that supports premium energy savings and comfort features. Carrier Performance variable speed fan coils (FV4C) can help improve your home heating or cooling system efficiency and comfort, while saving energy.The single point wiring kit acts as a jumper between L1 and L3 lugs, and between the L2 and L4 lugs. This allows the installer to run two heavy-gauge, high-voltage wires into the fan coil rather than 4 light-gauge, high-voltage wires. SUGGESTED USE: Fan coils with 15- and 20-kW fused heaters only.The FX4D fan coil is the Puron@ refrigeration design loaded with popular features. It comes in a pre-painted (taupe metallic) galvanized steel casing and is shipped with a cleanable, permanent framed filter, and a factory-supplied power plug. ArmorCoat provides a tin plating of the indoor coil's copper hairpins. Instructions supplied with kit for proper installation. See the Product Data or contact your supplier for the kit number. Use fireproof resilient gasket, 1/8" to ¼" (3 to 6 mm) thick, between duct, unit, and floor. NOTE: A gasket kit is also required for all downflow applications to maintain low air leak/low sweat performance. See the Product ... Product safety data sheets (SDS) are essential documents that provide valuable information about the potential hazards and safe handling practices of various substances. The first ...Carrier puts comfort where you need it with the performance ™ series 40MBDQ Ducted indoor unit. Designed to fit in-ceiling, under-the floor or vertically in the wall, it’s perfect for either a single or multi-zone ductless system. This model offers the convenience of a temperature-sensing handheld remote as well as customized comfort with ...A. Upflow Installation. If return air is to be ducted through a floor, set unit on floor over opening and use 1/8 to 1/4−in (3 to 6 mm) thick fireproof resilient gasket between duct, unit, and floor. Side return is a field option on slope coil models. Cut opening per dimensions.The coils are available for use in Puronr Refrigerant (R--410A) and R--22 systems. The CAPMP and CARMP are cased A--coils that are housed in a durable, 22 gauge, pre--painted taupe metallic cabinet. The fully- -insulated cabinet (foil faced with R- -2.1 insulation properties) provides for quiet, efficient operation of the evaporator coil.GH5S: Product Data Manufacturer reserves the right to change, at any time, specifications and designs without notice and without obligations. 3 Vapor Line Sizing and Cooling Capacity Loss Acceptable vapor line diameters provide adequate oil return to the compressor while avoiding excessive capacity loss. The suction line diametersCoil circuiting has also been updated to make the most of all Carrier heat pumps and air conditioners. Units come with solid state fan controls, 1-inch (25mm) thick insulation with R-value of 4.2, multi-speed motors, and fully-wettable coils.Carrier strives to improve on our founder’s breakthroughs, introducing new technologies that make life at home even cooler. Today, a nationwide network of experts continues to advance Willis Carrier’s lifework. Your expert Carrier dealer is equipped to evaluate your home and create a customized system designed around your lifestyle. MORE THAN AEASY TO INSTALL AND SERVICE. A- -coil design for maximum surface area. A13303. FMU4X & FMU4Z -- Uncased Horizontal Fan Coil (FMU4Z model shown) Multiple electrical, refrigerant lineset and drain line entry for application flexibility. Primary and secondary drain connections exit from the back or side of the cabinet.1 To the original owner, when product is used in an owner-occupied residence, a 10-year parts limited warranty and lifetime heat exchanger parts limited warranty upon timely registration of your new equipment. Parts limited warranty period is 5 years and heat exchanger warranty is reduced to 20-years if not registered within 90 days. Jurisdictions … Product Data. FV4B PerformancetSeries Fan Coil Sizes 002 Thru 006. Product Data. PREMIUM ENVIRONMENTALLY SOUND FAN COIL. The FV4B is the premium air handler combining the proven technology of Carrier fan coils with environmentally sound Purone refrigerant. TheFV4B achievesan operational advantage when the ECM (Electronically Commutated Motor ... Meets and exceeds ASHRAE 90.1 energy efficiency levels. New unit control board with intuitive quick fan speed adjustment. New direct drive - EcoBlue™ Technology indoor fan system uses Vane Axial fan design & electronically commutated motor. Single-stage cooling capacity 04-06 models, two-stage on 07-30 models. SEERs up to 14.0, IEER of 15.2.Carrier strives to improve on our founder’s breakthroughs, introducing new technologies that make life at home even cooler. Today, a nationwide network of experts continues to advance Willis Carrier’s lifework. Your expert Carrier dealer is equipped to evaluate your home and create a customized system designed around your lifestyle. MORE THAN AProduct Literature. You can always rely on your Carrier dealer for solutions to any problems you may have with your system. We’ve also made product literature, brochures, manuals, and more available, right at your fingertips.Overview. The Comfort ™ FX4D fan coil utilizes a high-efficiency, multi-speed blower motor to provide comfort options. Paired correctly with an outdoor air conditioner or heat pump, …The 58SB0A/58SB1A ComfortTM Series 4-way Multipoise Gas Furnaces feature Carrier’s QuieTechTM noise reduction system for incredibly quiet induced draft operation. Applications are easy with. 4-way multipoise design, through-the-furnace downflow venting, 13 different venting options, and designed for easy service access.Meets and exceeds ASHRAE 90.1 energy efficiency levels. New unit control board with intuitive quick fan speed adjustment. New direct drive - EcoBlue™ Technology indoor fan system uses Vane Axial fan design & electronically commutated motor. Single-stage cooling capacity 04-06 models, two-stage on 07-30 models. SEERs up to 14.0, IEER of 15.2.Overview. The EZ Flex system provides whole home air filtration using a high efficiency filter. The deep-pleated style of its MERV 10 filter keeps air flowing while removing 63% of airborne particles in micron size range 1.0 to 3.0. 1. …60 to 300 Nominal Tons. The AquaSnap® 30RB chiller is an effective all-in-one package that is easy to install and easy to own. The chiller costs less to purchase and install and then operates quietly and efficiently. Value-added features include rotary scroll compression, Puron® refrigerant (R-410A), a quiet AeroAcoustic™ fan system, easy ... Overview. Carrier’s patent-pending evaporator coil with Vertex™ technology features a V-shape coil design provides excellent heat transfer over the coil needed to keep your system operating at peak energy efficiency and delivering consistent comfort. The V-coil design has a lighter, corrosion-resistant aluminum construction that increases ... Overview. If you want performance without all the bells and whistles of a communicating system, consider this Performance series model. As an 80% furnace it is most suitable for areas with milder winters. You can pair it with a high-efficiency heat pump or air conditioner and gain a cooling efficiency boost from its variable speed blower. Discover the pros and cons of Heil and Carrier air conditioners to help you make an informed decision. Learn which one is the best fit for you. Expert Advice On Improving Your Home...Low Air Leakage Kit. This kit is available through MicroMetl and when installed as per the instructions provided in the kit, is designed to meet the stringent 1.4% air leakage @0.5” …The kit consists of 12 fan coil framed filters. These filters collect large dust particles from the return air entering the fan coil and prevents them from collecting on the coil. This process helps to keep the coil clean, which increases heat transfer and, in turn, the efficiency of the system. SUGGESTED USE: To replace filters in fan coils. Carrier strives to improve on our founder’s breakthroughs, introducing new technologies that make life at home even cooler. Today, a nationwide network of experts continues to advance Willis Carrier’s lifework. Your expert Carrier dealer is equipped to evaluate your home and create a customized system designed around your lifestyle. MORE THAN A Carrier strives to improve on our founder’s breakthroughs, introducing new technologies that make life at home even cooler. Today, a nationwide network of experts continues to advance Willis Carrier’s lifework. Your expert Carrier dealer is equipped to evaluate your home and create a customized system designed around your lifestyle. MORE THAN A An air handler unit, also known as fan coil unit, is an essential component of your home heating and cooling system. It is responsible for circulating conditioned air throughout the home. An air handler typically consists of a blower fan, an evaporator coil, and a filter and is usually installed indoors, either in a basement, attic, or closet.Product Data A11263 Representative drawing only. Some product models may vary. The 59TP6C Multipoise Variable 25-Speed Condensing Gas Furnace features the two-stage Performance™ System. The Comfort Heat® technology two-stage gas valve is at the heart of the comfort provided by this furnace, along with the variable-speed ECM blower motor, and38MURA: Product Data Manufacturer reserves the right to change, at any time, specif ications and designs without notice and without obligations. 2 MODEL NUMBER NOMENCLATURE A220411 A220412 NOMINAL CAPACITY 18 - 1.5 Tons 24 - 2 Tons 30 - 2.5 Tons 36 - 3 Tons 48 - 4 Tons 60 - 5 Tons A - REGULAR HEAT B - HIGH HEAT M M …The FB4C(S,Q)L018-060 size fan coils come equipped with a bleed port style, adjustable R-410A thermal expansion valve (TXV). The valve incorporates a 15% bleed port to ensure equalization during the off cycle and prevent compressor hard starts. The valve is also fully adjustable if this function is needed.

Simply select the product type, the model number and the literature you want and we'll get it to you at the click of a button. If the product information you seek is not listed, contact your local Carrier expert for assistance to satisfy your information and/or system needs. Carrier provides technical and marketing literature to support all of .... Car accident on 215 freeway today

carrier fj4d product data

In today’s fast-paced digital world, businesses are constantly looking for ways to gain a competitive edge. One area that is often overlooked but can have a significant impact on o...As an Energy Starr Partner, Carrier Corporation has determined that this product meets the Energy Starr guidelines for energy efficiency. Refer to the combination ratings in the Product Data for system combinations that meet Energy Starr guidelines. NOTE: Ratings contained in this document are subject to change at any time.Product Data. A10082. AIR HANDLER TECHNOLOGY AT ITS FINEST. The FB4C fan coil has the proven technology of Carrier fan coil units with Puron refrigerant as well as vertical and horizontal applications. The design features contoured condensate pans with rugged drain connections, ensuring thatlittle water is left in the unit at the end of the ...Product Data 38MARB Outdoor Unit Single Zone Ductless System Sizes 09 to 36. 2 Specifications subject to change without notice. 38MARB-01PD Inverter Technology The inverter driven compressor is designed to run at various input power frequencies (Hz) which controls the compressor’s motor speed. ...BEIJING, Aug. 25, 2022 /PRNewswire/ -- VNET Group, Inc. (NASDAQ: VNET) ('VNET' or the 'Company'),‎ a leading carrier- and cloud-neutral Internet d... BEIJING, Aug. 25, 2022 /PRNews...22-1845-16A-EN. Unique Cabinet Design. - Double Wall Foamed and Formed Cabinet System. - Water Proof Cabinet Design. - R-4.2 Insulating Value (Avg Insulating Value R-8.2) - Composite Cabinet Doors. - Sweat Eliminating Cabinet Design. - Loose Fiber Eliminating Cabinet Design. - Smooth Cleanable Cabinet Design. The pump is designed for quiet operation. The pump consists of two parts: an internal reservoir/sensor assembly, and a remote sound-shielded pump assembly. A liquid level sensor in the reservoir stops the cooling operation if the liquid level in the reservoir is unacceptable. Edition Date: 01/21. Catalog No. 40MAHB-01PD. LEGACYt LINE FAN COIL. SIZES 019 THRU 061. Product Data. The FX4D fan coils combine the proven technology of Bryant fan. coil units with Puron®, the environmentally sound refrigerant. These fan coils are loaded with popular features. Factory- -installed, refrigerant- -specific thermostatic expansion valves (TXV) are.Instructions supplied with kit for proper installation. See the Product Data or contact your supplier for the kit number. Use fireproof resilient gasket, 1/8" to ¼" (3 to 6 mm) thick, between duct, unit, and floor. NOTE: A gasket kit is also required for all downflow applications to maintain low air leak/low sweat performance. See the Product ...Carrier fan coils. It comes in a pre-painted galvanized steel casing with 1-in. insulation and has a 3-speed motor in the full range of sizes 018 through 070. All units are equipped with an AccuRater® metering device and are also shipped with a cleanable, permanent framed filter. The FC4C is a deluxe design fan coil incorporating all the featuresProduct Data FK4D PREFERREDt SERIES VARIABLE SPEED FAN COIL SIZES 001 THRU 006 FK4D PREMIUM AIR HANDLING TECHNOLOGY The FK4D is the latest in air handling technology. It is the perfect unit when you need a fan coil that can deliver high--tech performance, application versatility, easy installation, and high efficiency.The FB4C(S,Q)L018-060 size fan coils come equipped with a bleed port style, adjustable R-410A thermal expansion valve (TXV). The valve incorporates a 15% bleed port to ensure equalization during the off cycle and prevent compressor hard starts. The valve is also fully adjustable if this function is needed.EASY TO INSTALL AND SERVICE. A- -coil design for maximum surface area. A13303. FMU4X & FMU4Z -- Uncased Horizontal Fan Coil (FMU4Z model shown) Multiple electrical, refrigerant lineset and drain line entry for application flexibility. Primary and secondary drain connections exit from the back or side of the cabinet..

Popular Topics